433~480MHz, Gain51dB, Psat45dBm, SMA
To check stock availability, search under "In-stock Products" on the Dianzibuy store.
Any change to the content of this page is subject to change without notice. Please confirm the specifications before ordering.
Products must not be used for any unlawful purpose; the customer bears any loss arising from unlawful use.
Suitable for fields such as drone interference and aging testing.
| Parameters | Min | Typical | Max | Units |
|---|---|---|---|---|
| Frequency | 433 | ~ | 480 | MHz |
| Gain | 51 | dB | ||
| Gain flatness | ±1 | dB | ||
| Input VSWR | 1.4 | |||
| Psat | 44 | 45 | 46 | dBm |
| Max input power | 10 | dBm | ||
| ALC control range | 10 | dB | ||
| Gain Adjustment Range | 25 | dBc |
| Connector | SMA-K |
| Temperature protection | +85 ℃ over temperature alarm and shutdown, 65 ℃ open |
| Transmission and control interface | CMOS3.3V |
| Ripple | ≤2.5dB |
| Impedance | 50Ω |
| Working voltage | +28V |
| Working current | 4500mA |
| Operation Temp. | -40~+55℃ Design assurance |
| Gain adjustment accuracy | Attenuation of 10dB: ≤ ± 1dB; Attenuation of 20dB: ≤ ± 1dB; Attenuation of 25dB: ≤ ± 1.5dB |
| F (MHz) | Gain(dB) | Pout(SAT) | Ids(A) | IdQ(mA) |
|---|---|---|---|---|
| 420 | 48.93 | 44.55 | 2.26 | 400 |
| 430 | 49.67 | 45.31 | 2.6 | 400 |
| 440 | 50.77 | 46.21 | 3.06 | 400 |
| 450 | 51.74 | 47.33 | 3.48 | 400 |
| 460 | 52.38 | 47.08 | 3.26 | 400 |
| 470 | 52.3 | 44.85 | 2.82 | 400 |
| 480 | 51.43 | 44.53 | 2.96 | 400 |


RS485 interface
1) Settings: switch, gain;
2) Query: Module status (including amplifier status, over power alarm, over temperature alarm), amplifier temperature, amplifier ATT value, detected forward power;
3) Overpower alarm: If the power exceeds the maximum output power by+2dB, an alarm will be triggered;
4) Over temperature alarm: It is recommended to set the threshold to+85 ℃. If the temperature exceeds+85 ℃, an alarm should be triggered and the power amplifier should be turned off. When+65 ℃ is reached, the power amplifier should be turned on;
5) Temperature detection of power amplifier: The detection range is required to include but not limited to -25 ℃ to+85 ℃, and the detection accuracy is required to be ± 3 ℃;
6) Forward power detection: The detection range should be greater than 20dB, and the detection accuracy should be less than ± 1dB;
Store in an environment with a humidity of less than 25%, pay attention to dust and anti-static measures, and consider amplifier heat dissipation during installation.