17~32GHz, Gain60dB, Noise Temp.350K, P-1dB15dBm, 2.92
To check stock availability, search under "In-stock Products" on the Dianzibuy store.
Any change to the content of this page is subject to change without notice. Please confirm the specifications before ordering.
Products must not be used for any unlawful purpose; the customer bears any loss arising from unlawful use.
Broadband, low noise.
| Parameters | Min | Typical | Max | Units |
|---|---|---|---|---|
| Frequency | 17 | ~ | 32 | GHz |
| Gain | 60 | dB | ||
| Gain flatness | ±2.5 | dB | ||
| Noise Temp. | 350 | K | ||
| VSWR | 1.8 | |||
| P-1dB | 15 | dBm | ||
| Spurious suppression | 60 | dB |
| Connector | 2.92-K |
| Connector material | Stainless steel |
| Impedance | 50Ω |
| Surface | Gold-plating |
| Working voltage | +15V(+12V~+18V ) |
| Working current | 300mA |
| Relative humidity | 10%~100% Design assurance |
| Operation Temp. | -40~+75℃ Design assurance |
| Storage Temp. | -55~+85℃ Design assurance |
| Other | Maximum non damaging input level: 0dBm; Equipped with radiator. |
| Frequency GHz | VSWR | GaindB | P-1 out dBm | Psat dBm | ETK | NFdB |
|---|---|---|---|---|---|---|
| 15 | 1.84 | 68.82 | 14.3 | 15.8 | 251.15 | 2.71 |
| 16.43 | 1.35 | 65.97 | 17 | 18.1 | 203.99 | 2.31 |
| 17.86 | 1.24 | 65.17 | 18 | 18.7 | 197.16 | 2.25 |
| 19.29 | 1.67 | 65.91 | 18.8 | 19.4 | 187.68 | 2.17 |
| 20.71 | 1.58 | 65.9 | 19.3 | 19.6 | 175.72 | 2.06 |
| 22.14 | 1.42 | 65.42 | 19.1 | 19.5 | 225.6 | 2.5 |
| 23.57 | 1.36 | 64.51 | 19.1 | 19.4 | 242.04 | 2.64 |
| 25 | 1.4 | 62.78 | 19.8 | 20.3 | 227.71 | 2.52 |
| 26.43 | 1.52 | 62.09 | 19.3 | 20.4 | 279.99 | 2.93 |
| 27.86 | 1.59 | 62.19 | 19.7 | 21.1 | 241.14 | 2.63 |
| 29.29 | 1.49 | 63.22 | 19.7 | 21 | 178.52 | 2.08 |
| 30.71 | 1.32 | 65.21 | 19.6 | 20.8 | 199.35 | 2.27 |
| 32.14 | 1.46 | 66.41 | 19.4 | 20.7 | 230.87 | 2.54 |
| 33.57 | 1.86 | 63.77 | 19.5 | 20.4 | 237.26 | 2.6 |
| 35 | 3.87 | 55.62 | 19.4 | 20.2 | 253.69 | 2.73 |



Store in an environment with a humidity of less than 25% and pay attention to dust and static electricity prevention.
Send us your requirements — our engineers will respond within one working day.